TotalHeat Exchanger HRV (Heat Reclaim Ventilation) Operation manual HRV - Heat Reclaim Ventilation Before using the DAIKIN HRV, be sure to read this operation manual thoroughly. If you have any problems or there is a malfunction, please refer to this operation manual. Please keep this manual for your future reference Initiallyrolled out in1982, the Daikin VRV system has become a popular choice today in various parts of the world. In line to our commitment of developing best-in-class products, we have introduced VRV X system that is poised to strengthen our market leadership. The system now delivers an imrpoved line-up to meet an ever-evolving range of needs, while better energy savings, comfort and ease Diantaranyaunit Heat Reclaim Ventilator yang fungsi utamanya menjaga sirkulasi udara dalam ruang hingga VRV Home Series. Komitmen Daikin pada tujuan utamanya untuk meningkatkan wawasan bagi kedua profesi di bidang hunian ini, terlihat nyata pada keseriusan perusahaan ini dalam perhelatan Daikin Proshop Designer Award 2022. Ifyou have a Daikin split system, you can use your remote to self diagnose the problem! Tri-Tech's aircon experts explain how. (07) 3394 0222 Request a call . A malfunction of the heat reclaim ventilator; The door switch is open; The hot water temperature is too high; ventilationrate When many people are in the room, more fresh air is brought in to maintain comfortable CO 2 levels. When fewer people are in the room, energy is saved by bringing in less fresh air. 9 AM 12 PM 5 PM Heat reclaim ventilation Ventilation with heat recovery as standard › NEW Thinnest High Efficiency Enthalpy Heat Exchanger in the Getin-depth information on Daikin VAM150FCVE Heat Recovery Ventilators (HRV) including detailed technical specifications. Besides, view the entire catalog of Daikin VAM150FCVE Heat Recovery Ventilators (HRV) with specifications of other products from our extensive catalog from leading manufacturers of Heat Recovery Ventilators (HRV) Source any electronic HVAC product from over 20,000 products 33NJz8. Product Highlights Product Range Capacities View AR View 360 DX coil cooling capacity Airflow rate 500-950 m3 /h Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. Equipped with a heat reclaim ventilator and a heat exchanger DX coil, VKM series is capable of minimizing room temperature fluctuations. VKM series maintains comfortable indoor air quality IAQ by adding fresh outdoor air having nearly the same temperature and humidity conditions as the indoor air. Thus, VKM ensures optimum comfort and further reduces air conditioning load. VKM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VKM Supply Air duct. Heat Reclaim Ventilator + Heat Exchanger → Comfortable Air Supply Equipped with a heat reclaim ventilator and a heat exchanger, the new VKM series minimizes room temperature fluctuations. A Compact Unit Packed with Daikin’s Cutting-Edge Technologies. Air Conditioning and Outdoor Air Processing Can be Accomplished Using a Single System. When the VKM series units are connected, the total connection capacity index must be 50% to 130% of the capacity index of the outdoor units. Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. Tech specs Specifications ModelVKM50GCVEVKM80GCVEVKM100GCVE Power Consumption Heat Exchange modeW 270/230/170390/335/220440/370/260 Power Consumption Bypass modeW305/260/200390/335/220440/370/260 External static Pressure Pa210/170/140220/180/125170/120/90 Airflow rate m3/h500/500/440750/750/640950/950/820 Sound level Heat Exchange modedB43/ Sound level Bypass modedB43/41/ Temp exchange efficiency %76/76/ Enthalpy exchange efficiency %64/64/6766/66/6862/62/66 DX-coil Capacity kW Dimensions H x W x D387x1764x832387x1764x1214387x1764x1214 Machine weight kg92113115 You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE Residential Light Commercial Commercial Home > Commercial > Ventilation Units > Energy Recovery Ventilator VAM_GVJU Overview Features Resources This product is designed to maintain good indoor air quality by providing sufficient levels of fresh outside air and recover waste heat from extracted air leaving the conditioned zone. This new ERV unit is fully compatible with Daikin’s DIII-NET communications. Provides energy-saving heat recovery ventilation via a new heat exchanger with high temperature and enthalpy recovery efficiency Design flexibility thanks to high static pressure fans and the capability for use in a wide range of climates 5°F to 122°F DB and 80% RH or less* Wide range of functions such as independent operation, interlock with other HVAC systems and automatic night purge to reduce cooling loads and increase energy savings Interlocked simultaneous operation with VRV indoor units through a single controller Auto mode switches the ventilation mode total heat exchange mode to bypass mode according to the operating status of air conditioner system Pre-cooling/heating control function to delay the start of ventilation during air conditioner start-up for higher energy savings Supply and exhaust fresh-up operation modes to control pressure within a space Filter sign and display reset notifies when filter changes are required ESP as high as Sound levels as low as dBA for sound sensitive installation locations * Note Certified in accordance with the AHRI ERV Certification Program, which is based on AHRI Standard 1060. Certified units may be found in the AHRI Directory at Performance characteristics certified to AHRI Standard 1060 based on the following conditions - The cooling effectiveness shall be based on 95°F DB / 78°F WB for the entering supply air and 75°F DB / 63°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow. - The heating effectiveness shall be based on 35°F DB / 33°F WB for the entering supply air and 70°F DB / 58°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow. Available in Capacities Refrigerant Daikin also offers heat reclaim ventilator systems; our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range -15 to 50°C. These units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, ESP of up to 235Pa offers greater design flexibility to your air conditioning solution. Other features include Night Purge Operation night time free-cooling, interlocked operation with VRV Cassette presence sensor and optional CO2, indoor & outdoor humidity sensors for optimal operation. By incorporating heat reclaim ventilators into your air conditioning design, heat loads can be reduced and your plan size can be better optimised. Download Brochure Engineering Data All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions. Contact a Daikin Sales Engineer A Daikin Sales Engineer will assess, plan and install the right air conditioning solution for you, with creativity and sensitivity to the needs of your family or business. AAF offers a comprehensive air filtration portfolio to provide clean air solutions for commercial and industrial applications.

daikin heat reclaim ventilator